9• Avoid prolonged high relative humidity and do notallow condensation water.• Do not use any acetone for cleaning theunit! The unit housing is resist

Strany 3

102. System description and Delivery notesBYK-mac COLOR measures color traditionally atfive aspecular angles (15°/25°/45°/75°/110°) with a45° illumin

Strany 4 - Inhaltsverzeichnis

11BYK - mac COLOR* CM-6395BYK - mac COLOR Sensor CM-6396Comes complete with:Multi-angle spectrophotometer, black calibrationstandard, white calibratio

Strany 5

123. Power supplyBefore operating the instrument for the first time,please read the operating manual and takeparticular notice of the Safety Instructi

Strany 6 - 1. Safety instructions

13Power supplyRechargeable battery packTo operate the instrument with the rechargeablebattery pack, make sure it is inserted until it locksin place.Wh

Strany 7

14Charging the rechargeable battery packThe rechargeable battery pack is charged in thedocking station. Charging time is approx. 2 hours.1. Battery pa

Strany 8

151234675Controls4. ControlsMeasurement unit1 Mode scroll wheel: switch on and menu selection2 esc button: changes between main menu and measurement

Strany 9

16Getting started5. Getting startedTurning on the unitTo turn on the unit, press the mode scroll wheel orthe operate button.The main menu appears.For

Strany 10

17The following error messages might appear duringmeasurement.A warning signal is heard and the light diodes flashred. At the same time, a message app

Strany 11

186. CalibrateCalibration InformationStandardsThe instrument comes with 2 calibration standards.The black trap is used to perform the zeroreflectance

Strany 12

1BYK-macBYK-mac COLORManualPatent pending 269 021 053 E 1012BYK-Gardner GmbHLausitzer Str. 8D-82538 GeretsriedGermanyTel. 0-800-gardner(0-800-4273637)

Strany 13 - 3. Power supply

19CalibrateCalibration Notes• Dirt or dust in the optics area will cause aninaccurate calibration reading. Therefore, alwaysuse the protective cap, if

Strany 14

206.1 Cyan CheckChoose "Cyan Check" from the "Calibrate" menu.Open the cover of the cyan checking standard andposition the instrum

Strany 15

216.2 CalibrateTurn the unit on by pressing either the menu scrollwheel or the operate button.Choose the menu item Calibrate from the Calibratemenu.Re

Strany 16 - 4. Controls

22CalibrateWhen black trap calibration is completed, theinstrument must be placed on the white standard.Position the instrument as thoroughly on the w

Strany 17 - 5. Getting started

236.3 Effect CheckChoose "Absolute" from the "Measure" menu. Thebasic configuration is the average of threemeasurements.Open the c

Strany 18

247. Measurement techniquesIn order to obtain accurate and repeatablemeasurements, the bottom of the instrument mustbe aligned flat on the sample surf

Strany 19 - 6. Calibrate

258. MeasureSelect the menu item Measure by pressing theoperate button/scroll wheel.A selection menu appears.”Continue last series”: To continue the l

Strany 20

26Measure8.2 AbsoluteYou are asked if you like to continue the test series.Confirm by pressing the scroll wheel leads you tothe last test series.You c

Strany 21

27New StandardYou are asked to input a name. You can accept thepredefined suggestion or change the character byturning the scroll wheel. When you pres

Strany 22

28MeasureExisting standardChoose the appropriate standard from the list.You are asked to continue the last series.If you choose ”Yes”, you can directl

Strany 23

2Dear customer,thank you for having decided for a BYK-Gardnerproduct. BYK-Gardner is committed to providing youwith quality products and services. We

Strany 24

29MeasureAuto standardThe function „Auto Standard“ is displayed if at leastone standard is stored in the memory. Whenchoosing this function the closes

Strany 25 - 7. Measurement techniques

308.4 OrganizerAn organizer file defines a measurement sequencefor user guidance, e. g. measuring a car body withseveral checkzones. These files can b

Strany 26 - 8. Measure

31MeasureAfter the standard has been measured, or when it isalready stored in the instrument, the name of thecheckzone to be measured first, appears o

Strany 27

32MeasureDuring the measurement you have access toadditional functions by pressing the mode wheel.In case you took a false reading, you can delete the

Strany 28

33Delete9. DeleteSelect the menu item Delete by pressing theoperate button/scroll wheel.A selection menu appears.”Last Measurement”: To delete the las

Strany 29

349.2 CheckzoneTo delete a whole checkzone, choose the menuitem ”Delete checkzone” and press the mode wheel..The instrument is now ready again to meas

Strany 30

35DeleteTo delete test series in difference mode, you have tochoose the appropriate standard first and then thetest series to be deleted. Test series

Strany 31

3610. Data ViewYou can use this function to display the readings ofmeasurements stored in the instrument.10.1 Test seriesAbsoluteTo view the data of r

Strany 32

37Data ViewOrganizerTo view the data of an organizer, choose theappropriate organizer from the list.Then select parameter 2 (color) and the appropriat

Strany 33

38Data View10.2 StandardTo view the data of a standard, choose theappropriate standard from the menu.The data of the standard is displayed.

Strany 34 - 9. Delete

3Table of contentInhaltsverzeichnis1. Safety instructions ... 52. System des

Strany 35

3911. SetupIn the Setup menu you find functions to adjustgeneral settings for:Measurement parametersInstrumentCalibrate11.1 Measurement parametersMeas

Strany 36

4011.1.1.2 SMC - Statistical Measurement ControlHighlight the function with the scroll wheel. Pressingthe wheel activates or deactivates the function

Strany 37 - 10. Data View

41Setup11.1.2.1 AnglesYou can choose individual angles or ”All”.11.1.2.2 ScalesHere you can decide according to which color scaleresults are calculate

Strany 38

42Setup11.1.2.3 Illuminant/ObserverYou can choose among the illuminants/observersshown on the left side.11.1.3 Effect (only available with BYK-mac)Thi

Strany 39

43Setup11.1.4 Sample Temp AlarmThe device has a built in temperature sensor. If thealarm is activated, a checkmark appears.You can set minimum and max

Strany 40 - 11. Setup

44Setup11.2 InstrumentIn the Setup menu you find functions to adjustgeneral settings of the instrument:11.2.1 Sample curvatureYou can adapt the sensit

Strany 41

45Setup11.2.3 BeeperThis menu option turns the beeper on or off. Use thescroll wheel to move the cursor to Beeper and pressthe wheel.When the beeper i

Strany 42

46Setup11.2.6 Date/TimeThe unit contains an integrated clock. This makesdate and time of the measurement available for datatransfer to a PC. Date and

Strany 43

4711.2.8.1 Interrupt statisticIf interrupt statistic is activated you can interrupt acheckzone (sample) before reaching the presetnumber of measuremen

Strany 44

48Setup11.3 CalibrateYou can perform a cyan check and a completecalibration.Please refer to the chapter ”Calibration”.

Strany 45

412. Interface...4913. Standards...

Strany 46

4912. InterfaceTransfer of data stored in the memory of theinstrument takes place through the docking station.It contains the USB interface connectin

Strany 47

5013. StandardsDIN 5033 Colorimetry; basic concepts.DIN 5036 Radiometric and photometric properties of materials;definitions characteristic.DIN 6174 C

Strany 48

5114. Technical DataGeneral technical data:Temperature range 10 °C to 42 °C (50 °F to 110 °F)for operation0 °C to +60 °C (32 °F to 140 °F )for storage

Strany 49

52External power supply:External power supply Docking stationInput 90 - 264 VAC, 50 - 60 Hz max. 0,8 AOutput 12 VDC, 2,5 ATechnical Data

Strany 50 - 12. Interface

53Errors and Warning Messages15. Errors and Warning MessagesInfoWarningThe surface The sample temperature is lower than thetemperature is under ..°C s

Strany 51 - 13. Standards

54ErrorInstrument temperature Temperature is outside the operatingout of range temperature range.Ambient light Appears when there is too much ambientl

Strany 52 - 14. Technical Data

55Cleaning and Maintenance16. Cleaning and Maintenance• Do not insert any objects into the measurementaperture for cleaning. The instrument could getd

Strany 53

56Cleaning the Black TrapFrom time to time the black trap should be cleanedwith clean, dry air to remove any dust orcontamination.The black trap is ta

Strany 54

5717. Service and CertificationServiceBesides the repair of your instrument we offer thefollowing additional services:First diagnosis on the telephon

Strany 55

58Service and CertificationService Centers for BYK-Gardner productsGermanyBYK-Gardner GmbHLausitzer Strasse 882538 GeretsriedGermanyPhone:+49-8171-34

Strany 56 - 16. Cleaning and Maintenance

5Safety instructions1. Safety instructions • Before operating the instrument the first time,please read the operating instructions and takeparticular

Strany 57

5918. CopyrightThis instruction manual is an important part of this instrument. It contains es-sential information about setting up, placing in servic

Strany 58

269 021 053 E 1012

Strany 59

6Safety instructionsThe following symbols and terms are used.This symbol warns of the danger of injury.This symbol warns of the danger of injury cause

Strany 60 - 18. Copyright

7DANGER injuries possible• Defects and extraordinary loadsIf safe operation can no longer be presumed,shut down the device and secure it againstunint

Strany 61 - 269 021 053 E 1012

8Safety instructionsb) by disconnecting the power supply unit plug fromthe socketThe power supply unit can be disconnect from thepower supply by disco